B&K CT310 Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
CT600/602/610 and CT300/310 BKC-DIP Product Specific Appendices
Version 2.00.09
Updated 12/15/06
Page 19 of 48
RS-232 Feedback Selection set to Reply
Continuous Parameter Feedback
With firmware 2.01 and greater, System Parameter AE has been
changed to RS-232 Feedback Selection. Setting the RS-232
Feedback Selection to “Reply” allows the CT300/310/600/602/610
to automatically generate BKC-DIP Reply messages for changes
to Volume, Bass, Treble, Equalization, Source and Tuner
Frequency.
Below is an example of how the RS-232 Feedback Selection Reply
may be used as Volume Feedback from the CT300/310/600/602/610
for use with an external controller.
Step 1)
First, set the CT300/310/600/602/610 system parameter AE = 2,
RS-232 Feedback Selection set to Reply.
Next, initiate a Master Volume change by one of the following
methods:
B&K code set 11 (Logical Zone 11) IR Master Volume Up
B&K code set 11 (Logical Zone 11) IR Master Volume Down
Front Panel Volume Encoder up or down while set to Logical
Zone 11
The CT300/310/600/602/610 will automatically generate the
following BKC-DIP Reply message command:
(0,R,P0B=FF,1=28;) Logical Zone 11 current Preset Parameter
Volume value is set to 28 hex or 0dB (assumes 0dB is the
current setting).
Step 2)
The external control device should be set to Poll for any BKC-
DIP Reply messages and parse out the specific logical zone and
current Preset Parameter value of interest, in this case the
current Preset Parameter Volume value for Zone 11.
Step 3)
The external controller should use the CT610/310/600 Zone 11
current Preset Parameter Volume value of “28” hex to update
its GUI or status in an appropriate fashion.
RS-232 Feedback Selection set to Update
Previous to 2.01, BKC-DIP messages “Update”, “Get” and Reply”
commands were necessary for feedback. All current preset
parameters for all logical zones in the CT300/310/600/602/610
are available at anytime. Typically, an external controller
will use the Update message generated in response to a Front
Panel button press or received B&K IR code-set, to formulate a
BKC-DIP Get command. The returned BKC-DIP Reply message data
may be used to extract the desired current Preset Parameter(s)
and value(s) for use with updating its display requirements.