Many
Manuals
search
Kategorien
Marken
Startseite
B&K
Messen, Testen & Steuern
50 Series II
Bedienungsanleitung
B&K 50 Series II Bedienungsanleitung Seite 94
Herunterladen
Teilen
Teilen
Zu meinen Handbüchern hinzufügen
Drucken
Seite
/
102
Inhaltsverzeichnis
FEHLERBEHEBUNG
LESEZEICHEN
Bewertet
.
/ 5. Basierend auf
Kundenbewertungen
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
80
6
Specifications
Note:
All specifications apply to the unit after a temperature stabili
zation time
of 15 minutes
over an ambient temperature range of 23 °
C
±
5
°C. Specifications are subject to change
without notice.
Model
8600
8601
8602
Input Ratings
Input Voltage
0
–
120 V
0
–
120 V
0
–
500 V
Input
Current
Low
0
–
3 A
0
–
6 A
0
–
3 A
High
0
–
30 A
0
–
60 A
0
–
15 A
Input Power
150 W
250 W
200 W
Minimum
Operating
Voltage
Low
0.11 V at 3 A
0.18 V at 6 A
1 V at 3 A
High
1.1 V at 30 A
1.1 V at 60 A
4.5 V at
15
A
CV Mode
Range
Low
0
–
18 V
0
–
50 V
High
0
–
120 V
0
–
500 V
Resolution
Low
1 mV
High
10 mV
Accuracy
Low
±(0.05%+0.02%FS)
±(0.025%+0.05%FS)
±(0.05%+0.025%FS)
High
±(0.05%+0.025%FS)
±(0.025%+0.05%FS)
±(0.05%+0.025%FS)
CC Mode
Range
Low
0
–
3 A
0
–
6 A
0
–
3 A
High
0
–
30 A
0
–
60 A
0
–
15 A
Resolution
Low
0.1 mA
0.1 mA
0.1 mA
High
1 mA
1 mA
1 mA
Accuracy
Low
±(0.05%+0.05%FS)
High
±(0.05%+0.05%FS)
CR Mode
Range
Low
0.05 Ω –
10 Ω
0.3 Ω –
10 Ω
High
10 Ω
-
7.5 kΩ
Resolution
16 bit
Accuracy
Low
0.01%+0.08 S
High
0.01%+0.0008 S
CW Mode
Range
150 W
250 W
200 W
Resolution
10 mW
Accuracy
0.1% + 0.1%FS
0.2% + 0.2%FS
0.1% + 0.1%FS
1
2
...
89
90
91
92
93
94
95
96
97
98
99
100
101
102
Model: 8600, 8601, 8602
1
Safety Summary
3
AC line
4
Compliance Statements
9
CE Declaration of Conformity
10
Safety Symbols
11
Table of Contents
12
1 General Information
15
1.2 Package Contents
16
1.3 Product Dimensions
16
Figure 2 - Rear View
18
1.4 Rackmount Installation
19
1.5 Front Panel Overview
20
1.6 Rear Panel Overview
21
80.000V
22
12.000A
22
2 Getting Started
24
Fuse Requirements
25
Fuse Replacement
25
2.2 Input Connections
26
System Selftest . . .
27
Input Check
28
3 Front Panel Operation
30
SYSTEM MENU
31
Constant Current
32
Constant Voltage (CV) Mode
34
Constant Voltage
35
Constant Resistance
36
Constant Power (CW) Mode
37
Constant Power
38
INITIALIZE SYSTEM?
40
Configure Power-On State
41
Load On Knob
41
Configure Trigger Source
41
Display Input On Timer
45
DISPLAY ON TIMER
46
COMMUNICATION
47
CONFIG MENU
49
VON LATCH
51
PROTECT MENU
52
CR LED Function
58
Remote Sense
59
External Voltage Source
61
3.5 Short Operation
62
3.6 Transient Operation
63
TRANSITION
65
3.7 List Operation
68
EDIT LIST
69
3.8 Battery Test Function
72
10.000V
73
EDIT PROGRAM
76
PROGRAM
76
RECALL PROGRAM
80
OCP TEST
84
OPP TEST
87
4 Remote Operation
90
4.2 Remote Commands
91
5 Troubleshooting Guide
92
6 Specifications
94
(excludes
97
7 Calibration
98
INFORMATION
100
LIMITED THREE-YEAR WARRANTY
101
Kommentare zu diesen Handbüchern
Keine Kommentare
Publish
Verwandte Produkte und Handbücher für Messen, Testen & Steuern B&K 50 Series II
Messen, Testen & Steuern B&K 2250 Light Bedienungsanleitung
(12 Seiten)
Messen, Testen & Steuern B&K 2250 Light Bedienungsanleitung
(332 Seiten)
Messen, Testen & Steuern B&K 2250 Light Bedienungsanleitung
(212 Seiten)
Messen, Testen & Steuern B&K 2250 Light Bedienungsanleitung
(20 Seiten)
Messen, Testen & Steuern B&K 2250 Light Bedienungsanleitung
(122 Seiten)
Dokument drucken
Seite drucken 94
Kommentare zu diesen Handbüchern