B&K 2250 Light Bedienungsanleitung Seite 167

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 332
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 166
CHAPTER 14
Reverberation Time Software (Optional Module)
155
14.3 Displaying the Results
The Reverberation Time Measurement screen includes three tabs at the bottom: Overview,
Spectrum and Decay. The tabs allow you to choose different ways of displaying the
measurement results:
Overview: Shows the measurement positions in a table – one position per row. Use this to
get an overview of your measurements, to include/exclude positions from the spatial
average of all positions in the room, and to manage annotations/signal recordings at the
positions
Spectrum: Shows the reverberation spectra graphically, or as a table, for one position, or for
the room average. Alternatively, it can show the instantaneous sound pressure level while
measuring
Decay: Shows the reverberation decay at a single frequency, for one position, or for the
room average
14.3.1 Overview
The Overview tab shows the measurement positions in a table – one position per row.
Fig.14.6
Overview tab
Status Field
The Status Field consists of three lines (see Fig.14.6) – the first two lines of information are
common to the status lines in the Sound Level Meter and Frequency Analyzer (see Chapter 4).
Note: The first line of the Status Field might also contain a smiley, indicating the quality of the
room (the spatial average of all positions). See the description of smileys in the following
paragraph and section 14.5.
Seitenansicht 166
1 2 ... 162 163 164 165 166 167 168 169 170 171 172 ... 331 332

Kommentare zu diesen Handbüchern

Keine Kommentare